Erdni Fiber
Brooklyn, NY · Serving New York City

Commercial fiber, spliced, terminated and certified.

I'm Erdni, a fiber technician working in NYC commercial buildings and data centers. I install and splice fiber, terminate it, and test every link to TIA standards, then hand you results you can file.

TIA-598 fiber color code · strands 1 to 12

What I do

Single-mode and multimode, from a single strand to full riser and backbone runs.

Fusion splicing

Pigtail splicing into SC and LC adapter panels, splice trays, protection sleeves and enclosure dressing. Armored and plenum distribution cable prepped properly.

OS2 · OM3 · OM4

Termination

Field termination of LC and SC connectors, scoped and cleaned before anything gets plugged in. Corning and Panduit systems.

LC · SC · UPC · APC

MTP / MPO trunks and cassettes

Trunk installs, cassette and panel setup, polarity checked end to end. APC and UPC matched on every interface, because the two do not mix.

MTP · 8 / 12 / 24 fiber

Certification testing

Every link tested for loss against the TIA-568.3 limit and saved with a result you can hand to the client or the general contractor.

Fluke Versiv · Tier 1

Troubleshooting

Dead strand, high loss, a run nobody can find. I trace it, inspect the end-faces, and work out whether it is dirt, a bad connector, a bend or a break.

VFL · Scope · OTDR

MDF, IDF and riser work

Experience inside occupied commercial buildings: closets on every floor, risers, and data center rows, with the labeling to match.

Commercial · Data center

What gets tested

Loss is measured at the wavelengths the fiber is built for, using a one-jumper reference set fresh for the job, and compared against the standard's limit for that link.

FiberWavelengthsLimit
Multimode OM3 / OM4850 / 1300 nmTIA-568.3 multimode, calculated from the actual link length and connector count
Single-mode OS21310 / 1550 nmTIA-568.3 single-mode, inside-plant for in-building runs and outside-plant for runs between buildings

A failing result gets a reason, not just a red mark. Higher loss at 850 nm usually points to a dirty or damaged connector. Higher loss at 1300 nm usually points to a bend in the cable. That tells me where to look first.

How a job runs

  1. Scope it

    Confirm the fiber type, strand count, connector type and polish (green APC and blue UPC cannot be mixed), and where each end lands.

  2. Install, splice, terminate

    Pull or dress the cable, splice pigtails or terminate connectors, and label as I go.

  3. Inspect and clean

    Scope every end-face and clean it before it meets another connector. Most failed tests start here.

  4. Certify every link

    Set the reference, run the test on each strand, and save the result.

  5. Hand over

    You get the test results, labeled panels and a plain note on anything unusual I found on the way.

Who you're hiring

I run Erdni Fiber out of Brooklyn and I do the work myself. Most of my experience is in real NYC commercial buildings: working around tenants, finding the right closet, and getting links tested and signed off.

I speak English and Russian.

Gear

Testing
Fluke Versiv with CertiFiber Pro Quad and DSX
Splicing
Fujikura fusion splicer
Connectors
Corning UniCam, Panduit OptiCam, mechanical LC
Locating
Visual fault locator, fiber scope, OTDR

Request a quote

Send me what you know and I'll reply with a scope and a price. The more of this you can include, the faster the answer:

  • Building address and which floors or rooms
  • Single-mode or multimode, if you know
  • How many strands and what connector type
  • New install, splice, test only, or a problem to fix
  • When you need it done
Phone / text(347) 647-5481
AreaBrooklyn and all of NYC